단발Astm E114-15 인치 타입 1018 보정 시험 블록 탄소강 작은 이이더블유 2
-
윌리엄Astm E114-15 인치 타입 1018 보정 시험 블록 탄소강 작은 이이더블유 2
-
톰Astm E114-15 인치 타입 1018 보정 시험 블록 탄소강 작은 이이더블유 2
-
LeoAstm E114-15 인치 타입 1018 보정 시험 블록 탄소강 작은 이이더블유 2
Excellent anti-jamming performance X Ray Flaw Detectors for thin iron plate , aluminum

무료 샘플과 쿠폰을 받으려면 연락하세요.
왓츠앱:0086 18588475571
웨이 채팅: 0086 18588475571
스카이프: sales10@aixton.com
걱정이 있으시면 24시간 온라인 서비스를 제공합니다.
x강조하다 | x ray inspection equipment,industrial x ray machine |
---|
Directional radiation portable X-ray flaw detector
(Glass x-ray tube)
XXQ series are suitable for the material directional of thin iron plate, aluminum, rubber and so on, may get very good picture quality and clarity.
Feature:
●Checking the software and hardware itself after start the machine
●Excellent anti-jamming performance, which can adapt for field operation without power supply, because of the motor supports
●Can adjust exposure parameters with keys ( easy operation.)
●Has the function of Delay time opening HV. Convenient for operator keep away from dangerous field
●Can adjust high voltage slowly for protecting X-ray generator
●Automatically controlling according to 1:1 working and rest operating way, the longest continuous exposure period is 5 minutes.
●Including complete protecting system: over KV, over KV, low mA, over mA, over temperature and optical-sound alarming
●Convenient for repairing and maintenance
●Much more Substance for structure designing, much more convenient for local operation
●Time can be changed for±0.3 according to the power supply net to make the exposure more precise
Specification:
|
Output voltage (Kv) |
Input (KW) |
Focus spot (mm) |
Beam angle |
Max penetration (mm) |
Weight (KG) |
Dimensions (mm) |
||
Generator |
Controller |
Generator |
Controller |
||||||
XXQ-1005 |
50-100 |
1.2 |
0.8X0.8 |
40° |
7 |
8.5 |
11 |
Ф135x555 |
350x290x160 |
XXQ-1605 |
60-160 |
1.5 |
0.8X0.8 |
40° |
18 |
17 |
11 |
225x225x600 |
350x290x160 |
XXQ-2005 |
100-200 |
2.0 |
1.5X1.5 |
40°+5° |
29 |
22.5 |
11 |
280x280x650 |
350x290x160 |
XXQ-2505 |
150-250 |
2.5 |
2.0X2.0 |
40°+5° |
39 |
33.5 |
11 |
320x320x740 |
350x290x160 |
XXQ-3005 |
170-300 |
3.0 |
3.5X3.5 |
40°+5° |
50 |
42 |
11 |
335x335x835 |
350x290x160 |
XXQ-3205 |
180-320 |
3.2 |
4.0X4.0 |
40°+5° |
55 |
42 |
11 |
335x335x835 |
350x290x160 |
XXQ-3505 |
200-350 |
3.2 |
4.0X4.0 |
40°+5° |
60 |
42 |
11 |
335x335x835 |
350x290x160 |
Standard Delivery
Directional glass X-ray tube |
1 Pcs |
|
Generator |
1 Set |
|
High voltage joins cable |
1 Pcs |
25 Meters |
Controller |
1 Set |
|
Power cable |
1 Pcs |
10 Meters |
Grounding cable |
1 Pcs |
5 Meters |
Accessories |
1 Set |
|
(Including: alarm lamp, 1 Pcs; lead letter, 1 box; Film dark cassettes 5 pcs; intensifying screen 5 pcs; Wire penetrameter (IQI) 1 set; fuse1 pc) |
Panoramicradiation portableX-rayflaw detector
(Glass x-raytube)
XXH series are suitable for the welding line detection of little pipe.
Installing carrying wheel or pipeline creeping device, convenient to set up in pipeline (controller also may enter pipeline with generator together), once exposure complete one week welding line detection.
Feature:
●Checking the software and hardware itself after start the machine
●Excellent anti-jamming performance, which can adapt for field operation without power supply, because of the motor supports
●Can adjust exposure parameters with keys ( easy operation.)
●Has the function of Delay time opening HV. Convenient for operator keep away from dangerous field
●Can adjust high voltage slowly for protecting X-ray generator
●Automatically controlling according to 1:1 working and rest operating way, the longest continuous exposure period is 5 minutes.
●Including complete protecting system: over KV, over KV, low mA, over mA, over temperature and optical-sound alarming
●Convenient for repairing and maintenance
●Much more Substance for structure designing, much more convenient for local operation
●Time can be changed for±0.3 according to the power supply net to make the exposure more precise
Specification:
|
Output voltage (Kv) |
Input (KW) |
Focus spot (mm) |
Beam angle |
Max penetration (mm) |
Weight (KG) |
Dimensions (mm) |
||||
Level target |
Cone target |
Level target |
Cone target |
Generator |
Controller |
Generator |
Controller |
||||
XXH-1005 |
50-100 |
1.2 |
1.0x3.5 |
25°+5° |
|
8 |
|
8.5 |
9.4 |
Ф135x555 |
305x338x140 |
XXH-1605 |
60-160 |
1.5 |
1.0x3.5 |
25°+5° |
|
11 |
|
17 |
11 |
225x225x600 |
350x290x160 |
XXH-2005 |
100-200 |
2.0 |
1.0x3.5 |
25°+5° |
30°+5° |
27 |
24 |
22.5 |
11 |
280x280x650 |
350x290x160 |
XXH-2505 |
150-250 |
2.5 |
1.0x2.4 |
25°+5° |
30°+5° |
37 |
34 |
33.5 |
11 |
320x320x740 |
350x290x160 |
XXH-3005 |
170-300 |
3.0 |
1.0x3.5 |
25°+5° |
30°+5° |
47 |
40 |
42 |
11 |
335x335x835 |
350x290x160 |
XXH-3205 |
180-320 |
3.2 |
1.0X4.0 |
25°+5° |
30°+5° |
50 |
45 |
42 |
11 |
335x335x835 |
350x290x160 |
XXH-3505 |
200-350 |
3.2 |
1.0X4.0 |
25°+5° |
30°+5° |
55 |
52 |
42 |
11 |
335x335x835 |
350x290x160 |
Standard Delivery
Directional glass X-ray tube |
1 Pcs |
|
Generator |
1 Set |
|
High voltage joins cable |
1 Pcs |
25 Meters |
Controller |
1 Set |
|
Power cable |
1 Pcs |
10 Meters |
Grounding cable |
1 Pcs |
5 Meters |
Accessories |
1 Set |
|
(Including: alarm lamp, 1 Pcs; lead letter, 1 box; Film dark cassettes 5 pcs; intensifying screen 5 pcs; Wire penetrameter (IQI) 1 set; fuse1 pc) |
Directional radiation portable X-ray flaw detector
(Ceramic X-ray Tube)
XXGseries areceramic X-ray tube, both can be directional model and Panoramic, it is more durable than the glass tube: shake proof and long working life.
Feature:
●Checking the software and hardware itself after start the machine
●Excellent anti-jamming performance, which can adapt for field operation without power supply, because of the motor supports
●Can adjust exposure parameters with keys ( easy operation.)
●Has the function of Delay time opening HV. Convenient for operator keep away from dangerous field
●Can adjust high voltage slowly for protecting X-ray generator
●Automatically controlling according to 1:1 working and rest operating way, the longest continuous exposure period is 5 minutes.
●Including complete protecting system: over KV, over KV, low mA, over mA, over temperature and optical-sound alarming
●Convenient for repairing and maintenance
●Much more Substance for structure designing, much more convenient for local operation
●Time can be changed for±0.3 according to the power supply net to make the exposure more precise
Specification
|
Output voltage (Kv) |
Input (KW) |
Focus spot (mm) |
Beam angle |
Max penetration (mm) |
Weight (KG) |
Dimensions (mm) |
||
Generator |
Controller |
Generator |
Controller |
||||||
XXG-1605 |
60-160 |
1.5 |
0.8X0.8 |
40°+5° |
18 |
17 |
11 |
225x225x600 |
350x290x160 |
XXG-2005 |
100-200 |
2.0 |
2.0X2.0 |
40°+5° |
29 |
22.5 |
11 |
280x280x650 |
350x290x160 |
XXG-2505 |
150-250 |
2.5 |
2.0X2.0 |
40°+5° |
38 |
33.5 |
11 |
320x320x745 |
350x290x160 |
XXG-3005 |
170-300 |
3.0 |
2.5X2.5 |
40°+5° |
50 |
42 |
11 |
335x335x835 |
350x290x160 |
Panoramic radiation portable X-ray flaw detector
(Ceramic X-ray Tube)
XXGseries areceramic X-ray tube, both can be directional model and Panoramic, it is more durable than the glass tube: shake proof and long working life.
Feature:
●Checking the software and hardware itself after start the machine
●Excellent anti-jamming performance, which can adapt for field operation without power supply, because of the motor supports
●Can adjust exposure parameters with keys ( easy operation.)
●Has the function of Delay time opening HV. Convenient for operator keep away from dangerous field
●Can adjust high voltage slowly for protecting X-ray generator
●Automatically controlling according to 1:1 working and rest operating way, the longest continuous exposure period is 5 minutes.
●Including complete protecting system: over KV, over KV, low mA, over mA, over temperature and optical-sound alarming
●Convenient for repairing and maintenance
●Much more Substance for structure designing, much more convenient for local operation
●Time can be changed for±0.3 according to the power supply net to make the exposure more precise
Specification
|
Output voltage (Kv) |
Input (KW) |
Focus spot (mm) |
Beam angle |
Max penetration (mm) |