x측정 기술 | 에디 전류 | 동작 주파수 | 60KHz, 240KHz |
---|---|---|---|
디스플레이 화면 | 240X320 픽셀 TFT-LCD | L*B*H | 180*80*30mm |
무게 | 260g | 전원 공급 | 리?? 폴리머 배터리 |
강조하다 | eddy current testing machine,magnetic flaw detector |
Measurement The Purity Of Non-Ferrous Metals Portable Eddy Current Testing Equipment
HEC-102 portable eddy current electrical conductivity meter, which are designed for quick testing of material property, such as material separate,quality control,material state check and so on. The products use the electromagnetic induction principle, can test non-ferromagnetic materials Ti – Ag.
Working principle
Eddy current exam is an NDT method established on the basis of electromagnetic induction principle; it is suitable for the conductive materials. Put the conductor in the alternating magnetic field, if inductive current exists, namely eddy current. On account of the change of each conductor’s own factors (for example: conductivity, magnetic conductivity, shape, size and flaw, etc), will cause the change of the current, so we can use this phenomenon to judge the conductor’s character or state and whether flaw exists.
Eddy current test is to put the conductor close to the alternating current coil, the coil establishes alternating magnetic field, this alternating magnetic field transits the conductor, and has the electromagnetic induction with it, establishes eddy current in the conductor. The current in the conductor also can produce its own magnetic field and can change the alternating magnetic field to be strong or weak, then causes the change of the voltage and R resistance. Therefore if the conductor’s surface or the near surface has flaw or the metal material changes, the intensity and the distribution of the eddy current will also change, so as the change of the voltage and R resistance, according to this change, the eddy current may indirectly know about the flaw in the conductor and whether the performance of the metal material changed.
Main features
★HEC-102 use 12mm 60 KHz probe as standard, 8mm 60 KHz probe optional for small part testing
★HEC-102 use 60 KHz (aviation industry standard) to inspirit, the testing data can be read in two kinds of unit (%IACS and MS/m)
★The products can test electrical conductivity and resistivity at the same time, resistivity can be automatically calculated and display according to the conductivity measurement value.
★HEC-102 include the intelligent temperature and lift-off compensations, can guarantee the testing accuracy of each measurement
★The big typeface and the back light illumination designs are advantageous for users to take the testing data even in low light condition
★The products use the high property battery to make sure it keeps more running time, and easy to carry and to grasp hold
★English language operation menu
★It can store 1000 measurement data, moreover, users can use USB connect the meter to a PC to create testing report (HEC-102 only)
★The measuring unit can be set by itself
★Measuring range can be customized according to user needs
Application:
★ Absolute measurement of electrical conductivity of nearly all non-ferrous metals;(Ti – Ag)
★ In the aerospace and automotive industry,monitor the process of heat treatment, the strength and hardness of aluminum alloy
★Test the conductivity when the aluminum have not been oxidized
★ Measurement the purity of non-ferrous metals
★Test the resistivity of conductive materials
★Analyze thermal properties of materials
HEC-102 Technical parameters
Hand-held eddy current conductivity tester for NF-metals with automatic normalization of the conductivity values to 20°C through temperature sensor
Measurement technology | Eddy current | |
Operating frequency | 60KHz,120KHz | |
Display screen | 240X320 pixels TFT-LCD | |
Size L*B*H | 180*90*40 mm | |
Instrument case | Anti-intense impact, water-proofing polyester; Toolbox | |
Weight | 300g | |
conductivity standard block | Verify and guarantee temperature compensation | |
Measuring range | 0.5%IACS-110%IACS(0.29MS/m-64MS/m) | |
Distinguishing rate | 0.01% IACS | |
Probe compensated | 0.3mm | |
Measuring accuracy |
0°C to 45°C 23%IACS :±0.1%IACS 100%IACS:±0.3%IACS |
|
Temperature compensation | Automatic compensation to the value of 20 ℃ | |
Normal work environment | Relative humidity | 0~95% |
Operating temperature | 0℃~50℃ | |
Data storage | Can store 1000 measurement data | |
Probe |
Diameter: 12mm Applicable to minimum measuring area diameter at 60KHz is 12mm |
|
Diameter: 8mm Applicable to minimum measuring area diameter at 60KHz is 8mm |
Standard Accessories
Instrument Host HEC-102, Standard probe 12mm 60KHz , Probe cable, Conductivity standard block aluminum and copper each one, Power adapter, Insulation sleeve, Suitcase, Instrument manual, Calibration certificate
Optional Accessories
12mm 60KHz or 120KHz probe
8mm 120KHz or 240KHz probe
Other calibration blocks
Curve probe support for pipe testing
Curve probe support for pipe testing
Products use and maintain
Ⅰ,In order to prevent electric shock or catch fire, please use the suitable power adapter
Ⅱ,Avoid to drop and hit the instrument.
Ⅲ,Please keep the instrument clean and dry, please check the probe and standard block weather are damaged or corrupted before using.
Ⅳ,Please do not operate in wet, explosive, chemic or high temperature environment.
Ⅴ,Do not voluntarily replace the spare part, if the product is abnormal or has suspicious breakdown, please contact with technology department or serviceman of our company for help.